Maintenance of cold storage condensing units

Daily maintenance and upkeep of cold storage refrigeration condensing units include: During the initial operation of the condensing unit, we should always observe the oil level, oil return and cleanliness of the cold room compressor. If the oil is dirty or the oil level drops, we should promptly notify us to change the oil or add oil to avoid poor lubrication…
https://www.coolerfreezerunit.com/air-cooler-condenser-unit/

1. During the initial operation of the condensing unit, you should always observe the oil level, oil return and cleanliness of the compressor. If you find that the oil is dirty or the oil level drops, you should notify us in time to change the oil or add oil to avoid poor lubrication.

2. For air-cooled condensing units, you should clean the air cooler frequently to maintain a good heat exchange state. At the same time, you should always check the scaling of the condenser and remove the scale in time. Cold storage project

3. For water-cooled condensing units, the degree of corrosion of cooling water should be checked regularly. If the cooling water is too dirty, it should be replaced. Check whether the water supply system has any problems such as running, bubbling, dripping, or leaking. Check whether the water pump is working properly, whether the valve switch is effective, and whether the cooling tower and fan are normal. If any abnormality is found, please notify us in time to deal with it.
5

4. Regularly observe the operating status of the compressor and check its exhaust temperature. Pay special attention to the operating status of the system during seasonal operation. If any abnormality is found, please notify us in time to adjust the system liquid supply and condensing temperature.

5. Regularly observe the operating status of the compressor and check its exhaust temperature. Pay special attention to the operating status of the system during seasonal operation. If any abnormality is found, notify us in time to adjust the system liquid supply and condensing temperature.

6. Listen carefully to the operating sound of the compressor, cooling tower, water pump or condenser fan. If any abnormality is found, it should be handled in time. At the same time, check the vibration of the compressor, exhaust pipe and foot.

7. Maintenance of the compressor: The refrigerant oil and dry filter need to be replaced once after 30 days of operation; replace it again after half a year of operation, and then it depends on the actual situation.